MSW 4V SDI rs • Installation and Operation

Installation and Operation

MSW 4V SDI rs • Installation and Operation

2-2

2-3

Installation

The 1U high, quarter rack width MSW 4V SDI rs can be

mounted on a rack shelf, under a desk, or on a tabletop.

Rack mounting

For optional rack mounting, mount the MSW on any of the

following rack shelves:
• RSF 123 1U 3.5" Versatools

®

Rack Shelf Kit

(part #60-190-20) (figure 2-1)

• RSB 123 1U 3.5" Versatools Basic Rack Shelf

(part #60-604-20)

• RSU 126 1U 6" Universal Rack Shelf Kit (part #60-190-10)
• RSB 126 1U 6" Basic Rack Shelf (part #60-604-10)
• RSU 129 1U 9.5" Universal Rack Shelf Kit

(part #60-190-01) (figure 2-2)

• RSB 129 1U 9.5" Basic Rack Shelf (part #60-604-01)

UL requirements

The following Underwriters Laboratories (UL) requirements

pertain to the safe installation of the MSW on a rack.
1

.

Elevated operating ambient temperature — If installed in a

closed or multi-unit rack assembly, the operating ambient

temperature of the rack environment may be greater than

room ambient temperature. Therefore, install the MSW in

an environment compatible with the maximum ambient

temperature (Tma = +122 °F, +50 °C) specified by Extron.

2

.

Reduced air flow — Install the equipment in a rack so that

the amount of air flow required for safe operation of the

equipment is not compromised.

3

. Mechanical loading — Mount the equipment in the rack so

that a hazardous condition is not achieved due to uneven

mechanical loading.

4

. Circuit overloading — Connect the equipment to

the supply circuit and consider the effect that circuit

overloading might have on overcurrent protection and

supply wiring. Appropriate consideration of equipment

nameplate ratings should be used when addressing this

concern.

5

. Reliable earthing (grounding) — Maintain reliable

grounding of rack-mounted equipment. Pay particular

attention to supply connections other than direct

connections to the branch circuit (e.g., use of power strips).

Mounting instructions

On the standard rack shelf, the MSW mounts in one of four

locations to the rear of the rack or in one of four locations to the

front of the rack.
1

.

If they are installed, remove the feet from the bottom of the

MSW.

2

.

Mount the MSW on the rack shelf, using two 4-40 x 3/16"

screws in opposite (diagonal) corners to secure the MSW to

the shelf.

3

.

Install blank panel(s) or other unit(s) to the rack shelf.

N

Only products in the VersaTools line can be mounted

to a VersaTools shelf. Most 1U rack-mountable Extron

products can be mounted on the standard shelf.

(2) 4-40 x 3/16" Screws

Use 2 mounting holes on

opposite corners.

1U Rack Shelf

1/4 Rack Width False Front

Face Plate

A/V SWITCHER

AUTO

SW

ICH

MOD

E

NOR

MAL

AUTO

1

2

3

4

A/V SWITCHER

AUTO

SW

ICH

MOD

E

NOR

MAL

AUTO

1

2

3

4

A/V SWITCHER

AUTO

SW

ICH

MOD

E

NOR

MAL

AUTO

1

2

3

4

Figure 2-1 — MSW mounted on a VersaTools rack
shelf

A/V S

WIT

CHE

R

MOD

E

NOR

MAL

AUTO

AUTO

SWIT

CH

1

2

3

4

A/V S

WIT

CHE

R

MOD

E

NOR

MAL

AUTO

AUTO

SWIT

CH

1

2

3

4

Figure 2-2 — MSW mounted on a standard rack shelf