Installation and Operation, cont’d

2-6

MSW 4V SDI rs • Installation and Operation

2-7

See chapter 3, “Serial Communication” for Simple Instruction

Set (SIS) commands to communicate with the MSW 4V SDI rs

via RS-232.

d

Contact connector

— Connect a remote contact

closure device to the MSW for remote control

of the switcher, or daisy chain it to other MSWs

for remote control of all the units, via this 5-pin

captive screw connector.

N

The switcher must be in normal (manual) mode for contact

closure to work. See "Mode selection", later in this

chapter.

To select an input using a contact closure device, such as an

Extron CCR 204 contact closure remote control (part #60-794-02)

or a locally constructed device, momentarily short the pin for

the desired input number to logic ground (pin 5). To force one

of the inputs to be always selected, leave the short in place. The

short overrides any front panel input selections.

You can also daisy chain multiple MSWs via the Contact

connector for front panel control of all switchers; touch the input

button on one MSW to switch all MSWs. Wire pin 1 to pin 1,

pin 2 to pin 2, and so on.

e

Power connector — Plug the external 12 VDC power supply

into this 2-pin, 3.5 mm captive screw connector. The power

supply is included with the unit.
In the event that power is disconnected from the MSW, the unit

retains mode and input settings.

N

The power connector on the rear panel is orange; however,

the plug for the power cord may be either orange or

blue. Either color plug can be connected to the rear panel

receptacle.

To wire the connector, do the following:
1.

Cut the DC output cord to the length needed.

2.

Strip the jacket to expose 0.2” (5 mm) of the conductors for

the blue captive screw plug, or 0.3” (7 mm) for the orange

plug.

Power Supply

Output Cord

Orange Captive Screw

Connector

0.3” (7 mm) MAX

SECTION A–A

Ridges

Smooth

A

A

Tie Wrap

Figure 2-6 — Power wiring

W

Exposing more than the amount of wire described

above could allow the stripped wires to touch each

other, causing a short circuit. This could result in

the external DC power supply overheating and/or

burning.

N

Stripping the wires to expose less than the recommended

amount causes them to slide out of the connector too easily,

even if they are tightly pinched by the captive screws.

3.

Slide the leads into the supplied captive screw plug and

lock them, using an Extron Tweeker (small screwdriver).

4.

Use the supplied tie-wrap to strap the power cord to the

extended tail of the connector.

5.

To verify the power cord’s polarity before connecting

it, plug in the power supply with no load and check the

output with a voltmeter.

C

Do not tin the stripped power supply leads before

installing the captive screw connector. Tinned

wires are not as secure in the captive screw

connectors and can be easily pulled out. They may

also break after being bent several times.

W

The two power cord wires must be kept separate

while the power supply is plugged in. Remove

power before wiring.

Alternately, an Extron PS 123 12 VDC, 3 amp power supply,

(part #60-814-01), can power up to eight MSWs or other Extron

12 VDC devices using only one AC power connector.