27 Design LED Par Zoom MH™

activated, the keys will be automatically locked in 15 seconds from the last press. In
order to deactivate the keylock status, press the Mode/Esc-button for 3 seconds.

1. Access the main menu.

2.

Tap the UP button until “DISP” is displayed.

3.

Press ENTER, the display will show “VALU”.

4.

Tap the UP button until ”LOCK” is displayed and tap the ENTER button.

5.

Press the UP button to select “ON” to activate this function, or “OFF” to deactivate

this function.

6.

Press ENTER to confirm.

7.

Press MENU to return to the main menu.

12. SPEC MENU – This menu option access all the special functions listed below.

RDMX

– This function allows the DMX address to remotely be adjusted from a DMX

console. This setting requires special settings for both the controller and the fixture.

RDMX is on by default. For proper DMX addressing uing the RDMX function see DMX

addressing Section 9/ Page 34.

DFSE

- With this function you can restore the factory default settings of the fixture. All

settings will be set back to the default values. Any edited scenes will be lost. When

restoring the factory settings the unit must be set to the address that the unit was in

when you started editing. When you confirm this function, the fixture will begin to

reload the original factory settings.

1. Access the main menu.

2. Tap the UP button until “SPEC” is displayed, press ENTER.

3. Tap the UP button until “DFSE” is displayed, press ENTER.

4. The display will show “ON/OFF.”

5. Press the UP button to display “ON” to activate this function, or “OFF” to

deactivate this function.

6. Press ENTER to confirm.

7. Press MODE/ESC to return to the main menu.