NetMax N8000 System Controller

Owner’s manual

Performance Specifications

According to the ISO 11898-2 standard, CAN-bus data transfer cabling has to be carried out
using Twisted-Pair cables with or without shielding providing a characteristic impedance of 120

Ω. Both ends of a CAN-bus need to be terminated with 120 Ω termination-plugs. The maximum
bus-length depends on the actual data transfer rate, the kind of data transfer cable being used,
as well as the total number of participants on the bus. The following table shows the most
essential requirements for CAN-networks consisting of up to 64 participants.

* With longer cables and many participants on the CAN-bus, termination resistors with higher
impedance than the specified 120

Ω are recommended to reduce the ohmic load of the interface

drivers and therefore the voltage drop between the two cable-ends.

The following table is meant for first assessment of necessary cable diameters for different bus
lengths and bus-participant numbers.

Additionally, the length of branch lines - for participants that are not directly connected to the
CAN-bus - is also of importance. For data transfer rates of up to 125 kbit/s, the maximum length
of a single stub cable should not exceed 2 meters. For higher bit rates a maximum length of only
0.3 meter is still permissible. The entire length of all branch lines should not exceed 30 meters.

General Note:

As long as only short distances (up to 10 meters) are concerned, common RJ-45 patch
cables with a characteristic impedance of 100

Ω (AWG 24 / AWG 26) can be used for the

cabling inside of a rack mounted system.

The previously outlined guidelines for network cabling are mandatory as far as the rack
mounted shelve interconnection or fixed installations are involved.

Bus Length (in m)

Date Transmission Cable

Termination (in

Ω)

Max. Data Transfer

Rate

Resistance per

Unit Length

(in m

Ω/m)

Cable Diameter

0...40

< 70

0,25...0,34 mm²

AWG23, AWG22

124

1000 kbit/s at 40 m

40...300

< 60

0,34...0,6 mm²

AWG22, AWG20

127

500 kbit/s at 100 m

300 ... 600

< 40

0,5...0,6 mm²

AWG 20

150...300*

100 kbit/s at 500 m

600...1000

< 26

0,75...0,8 mm²

AWG 18

150...300*

62,5 kbit/s at 1000 m

Bus Length (in m)

Number of Units on the CAN-Bus

32

64

100

100

0,25 mm² bzw. AWG24

0,34 mm² bzw. AWG22

0,34 mm² bzw. AWG22

250

0,34 mm² bzw. AWG22

0,5 mm² bzw. AWG20

0,5 mm² bzw. AWG20

500

0,75 mm² bzw. AWG18

0,75 mm² bzw. AWG18

1,0 mm² bzw. AWG17

Advertising