Osd manual, Exposure, Shutter (sub menu) – EverFocus HD CCTV EQH5000 User Manual

Page 21

Advertising
background image

22

9. OSD MANUAL

EXPOSURE

- BRIGHTNESS

Same as the BRIGHTNESS value in LENS

Menu. Using Left / Right button, adjust

Brightness value.
- SHUTTER

Using Set button, go to the SHUTTER sub

menu.
- AGC MAX

Using Left / Right button, adjust AGC Max

value.
- BLC

Using Left / Right button, select on/off of Back-

Light Compensation Control.

SHUTTER (Sub Menu)

- MODE

Using Left / Right button, select Shutter Control
modes – AUTO, MANUAL and FLK 60Hz
(FLK 50Hz).

AUTO

Auto Exposure mode

MANUAL

Manual Exposure mode

FLK 60Hz (FLK 50Hz) Flickerless mode (Default)

- SHUT LEVEL (Shutter Level)

This menu can be accessed when the Shutter Speed is set to MANUAL.
Use the Left / Right button to adjust the shutter speed control level.
Instead of using the default conventional shutter speed of 1/60,
you may choose other speeds. The speeds corresponding to the value of shutter
level are listed below.

Shutter
Speed

1/50 1/60

1/100 1/120 1/250 1/500 1/700 1/

1000

1/
1600

1/
2500

1/
5000

1/
7000

1/
10000

Level

178

169

142

135

105

65

46

32

20

12

6

4

3

[ EXPOSURE ]

BRIGHTNESS

SHUTTER

AGC MAX

BLC

ESC

EXIT

SAVE & EXIT

123

AUTO

10

OFF

[ SHUTTER ]

MODE

SHUT LEVEL

ESC

EXIT

SAVE & EXIT

MANUAL

1

Advertising