FREESTANDING INSTALLATION

Approved Venting Method 2: Through the Ceiling

 Venting through the ceiling/roof may be the only

feasible venting option in some cases and is a factory
recommended installation.

 When installing any venting system, Type L or Type

PL pipe must be used and all clearances to combustibles
listed by the pipe manufacturer must be strictly adhered
to.

 Use the pipe manufacturer’s approved ceiling support

for passing through a combustible ceiling, as well as the
required firestops, radiation shields, flashing and storm
collar.

 Be certain to follow the manufacturer’s required height

of termination above the roof line, and maintain at least
the minimum clearances to combustibles.

 Use an appliance collar where the pellet vent connects

to the exhaust output of the pellet stove and attach the
appliance collar to the exhaust blower output using three
sheet metal screws.

 Seal each pipe connection joint with high temperature

RTV Silicone, to ensure the system is leak free (Check
with the specific pipe manufacturer’s instructions before

doing so).

 If the pellet vent pipe being used is not a “Twist Lock” system, three (3) sheet metal screws

are required at each pipe joint.

 Connect the pellet stove to outside combustion air using the kit included with your stove or

using an alternative method, as described in the “Outside Air” section, on page 15.

 This venting method can also be modified so that the venting system runs horizontally

through the wall from the stove, then transitions to vertical and terminates above the roofline.
When using this modified version of this installation be certain to carefully follow the
venting system manufacturer’s instructions diligently.

Please Note:
Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual
installation. Please follow all venting system requirements, maintain the required clearances to combustibles, and follow all local
codes.

For high altitude installations (above 4,000 ft.), the vent pipe should be

increased from 3-inch (3”) to four-inch (4”).