25

6.1 Replacing the lamp

30 hours before the end of the lamp’s life time, the warning message “Lamp life
time is up! Replacement suggested!” will display on the screen. Please replace the
lamp immediately.

Steps:
1. Power off the projector.
2. Unplug the power cord.
3. Cool down projector for at least 30 minutes.
4. Use a screwdriver to remove the shell and screws on the lamp.
5. Remove lamp.
6. Gently process the new lamp module into the lamp bay, then replaces the lamp

module retaining screws.

7. Replace the lamp bay access panel, and then replace the access panel screw.

6.2 Cleaning lens

Please follow these steps to clean the projector lens:
1 Pour

an

adequate amount of cleanser to a piece of clean soft material. The lens

will be damaged if you use the cleanser containing particles, solvent, or other
inferior chemical solvent.

2 Use the soft material to wipe the lens in a circular direction.
3 Cover the lens with the cap if you are not going to use the projector right away.

Remove screws from the lamp
cover with a screwdriver; and
then press down the lock to
open that cover.

Remove 3 screws from
the lamp holder; and
pull out the handle to
replace the lamp in the
holder.

Advertising