Trouble shooting, Display does not show an image, Dvi 104 – Extron electronic DVI 104 Tx/Rx User Manual

Page 12: Tx/rx, cont’d, Normal position adjusted position

Advertising
background image

DVI 104 Tx/Rx • User’s Guide

DVI 104

Tx/Rx, cont’d

8

Trouble Shooting

Display does not show an image

Ensure that all plugs and jacks used by the external power

supplies are firmly connected.

If the cable is loose or slips out of the slot easily, move the

release catch from its normal position above the locking

catch, to the adjusted position under the locking catch

(see the figure below). This provides the extra leverage

required to keep the locking catch in place and hold the

cable securely.

Normal Position

Adjusted Position

Locking catch

Release catch

Ensure that the blue LEDs for both the transmitter and

receiver are on.

Ensure that the source device and output device are

powered on and have booted correctly.

Ensure that the fiber optic cables are connecting the correct

ports. A port on the transmitter must be connected to the

same numbered port on the receiver. For example,

port 1 of the transmitter must be connected to port 1 of the

receiver.

Ensure that the fiber optic cable jacks are securely seated.

Ensure that the transmitter is firmly plugged into the

source device and the receiver is firmly plugged into the

output device.

Try resetting the system by unplugging and reconnecting

the DVI connectors or the power jacks.

Try rebooting the computer.

Advertising