1-3. TROUBLESHOOTING
(Continued)

Problem

Cause

Correction

The evaporator is iced-up

Faulty de-icing heater

Replace de-icing heater

after a De-icing Cycle

Evaporator temperature at end

Increase the setting of step 8, in

of De-icing Cycle too low

Programming Section of
Operator’s Manual

Maximum time of De-icing Cycle

Increase the setting of step 7, in

too short

Programming Section of
Operator’s Manual

Too much water on evaporator

The unit has been shut down without

Start a De-icing Cycle

fins

a De-icing Cycle

Slow to decrease

Compressor not working properly

Check compressor and re-

in temperature (decline in

place if necessary

performance)

Evaporator fan not working properly

Check the fan and replace if
necessary

Temperature of room too high

Ventilate the room

Not enough clearance around unit

Relocate the unit; see Location

Section of the Operator’s
Manual