Henny Penny BCM-110 User Manual

Page 8

Advertising
background image

Model BCF-24/65/110, BCM-110

1-3. TROUBLESHOOTING
(Continued)

Problem

Cause

Correction

Green compressor indicator

Voltage across terminals 10-11

light off and compressor

of control board:

is working

- Control board relay bad

Replace control board

No voltage across terminals 10-11
of control board:
- Faulty contactor

Replace contactor

Green fan indicator light

Voltage across terminals 8-9 of

on and fan(s) not working

control board.
- Fan or capacitor bad

Replace fan or its capacitor

- Fan thermo-switch tripped

Allow the fan motor to cool to
see if the fan comes back on;
if the fan does not come back
on, or it keeps tripping, re-
place the fan

No voltage across terminals 8-9
of control board:
- Faulty control board relay

Replace control board

All indicator lights off and

Check electrical supply

Plug unit into receptacle, or

ON/OFF switch will not

reset wall circuit breaker

operate

Fuse of control board blown

Change the fuse

No voltage from the control

Change the control board

board transformer

Connector between the control

Check the connection

board and display board not
connected properly

Bad wire in the connector between

Replace the connector

the control board and display
board