CT87A,B,J ROUND® THERMOSTAT

11

69-0274-6

Check cooling

IMPORTANT: To avoid damaging the compressor in the air conditioner,

do not operate the cooling system when the outdoor temperature is

below 50°F (10°C).

1. If your CT87 has a subbase, set the System switch on the left to

Cool.

IMPORTANT: After heating is tested, wait five minutes before switch-

ing to Cool on the CT87J model.

2. Lower the temperature setting below room temperature. The cooling

system should start.

3. Raise the temperature setting above room temperature. The cooling

system should stop.

To set the temperature, turn the dial until the pointer on the top setting scale aligns with

the desired temperature.

CT87B, J switches

Switch

Setting

Result

System

Cool

The thermostat controls your cooling system.

Off

Both the heating and cooling systems are off.

Heat

The thermostat controls your heating system.

Fan

On

The fan runs continuously.

Auto

The fan runs only with the heating or cooling

system.

Operation