If installing on an outlet box – Honeywell CT87A User Manual

Page 4

Advertising
background image

CT87A,B,J ROUND® THERMOSTAT

69-0274-6

4

1. If using the cover ring: Position the cover ring against the wall so

that the arrow in the middle of the cover ring is pointing up.

2. Position the wallplate or subbase.

If using cover ring: Place the wallplate/subbase over the cover

ring. Rotate the wallplate/subbase until the wiring openings are

aligned and the two screw holes on the left and right side of the

wallplate/subbase align with the screw holes on the cover ring.

You will be inserting screws through these holes into the wall.

If attaching wallplate directly to the wall: Position so that the

UP indicator on the wallplate is on top.

If attaching subbase directly to the wall: Position so that the

fan and heating/cooling switches are on the top.

3. Use a pencil to mark the center of the screw holes on the left and

right sides of the wallplate or subbase.

4. Remove the wallplate/subbase and cover ring, and drill two 1/16-in.

holes at the locations you marked.

5. Reposition the cover ring (if used) and wallplate/subbase over the

holes, pull the wires through the wiring opening, and loosely insert

the two 1-in. screws into the drilled holes.

If installing on an outlet box

Refer to Fig. 5 as you work.

Fig. 5. Installing wallplate/subbase on an outlet box (subbase shown).

M20187

OUTLET BOX

SUBBASE

COVER RING

1

THERMOSTAT
WIRING HOLE

THE TWO INNER HOLES ARE USED WITH WALLPLATE.

2

IF OUTLET BOX IS HORIZONTAL, MOUNT COVER RING IN
POSITION SHOWN, BUT FASTEN WITH SCREWS THROUGH "A".

2

1

A

1/2 IN. BINDING
HEAD SCREW (2)

1/4 IN.
ROUND
HEAD
SCREW (2)