Wire the thermostat

1. Use the wiring cross-reference table below to match each old

thermostat wire with its corresponding terminal on the CT87 wallplate

or subbase. See Fig. 8 through 13 wiring diagrams.

*Never attach wires to both the B and O terminals.

2. Strip the wire insulation as needed to fit the wires underneath the ter-

minal screws (Fig. 7).

3. Loosen the terminal screws and slip each wire beneath its matching

terminal.

4. Securely tighten the terminal screws.

5. Push any excess wire back into the wall.

Wiring Cross-reference

Wire Label

Connect to

CT87A

Connect to

CT87B

Connect to

CT87J

R, RH, 4, V

R

RH

R

Rc, R

Rc

W, W

1

, H

W

W

W

Y, Y

1

, M

Y

Y

Y

G, F

G

G

B

See Fig. 9

B*

O

O*

See Fig. 13

P

6

Fig. 7. Fitting wires under the terminal screws.

M1279

FOR STRAIGHT
CONNECTION—
STRIP 5/16 in. [8 mm]

FOR WRAPAROUND
CONNECTION—
STRIP 7/16 in. [11 mm]

BARRIER