32

Problem

Cause

Solution

Automatic icemaker
The

icemaker

has stopped

making ice.

• The ice cube height sensor

arm has detected a full

tray condition.

• The water supply valve is

closed.

• The freezer section is not

cold enough.

• The water source saddle

valve is somehow blocked.

• To make more ice cubes you

may need to distribute your ice

to the center drawer right side

(or lower drawer) to increase

ice cube harvest volume.

• Turn on the water supply valve.
• Adjust the setting in the freezer

to a colder setting and allow it

to balance within 24 hours.

• Check the water supply

saddles valve for obstruction

and replace it if damaged.

The ice

making

capacity is

low.

• The freezer drawer area is

not cold enough.

• The water supply valve

does not have enough

pressure or does not open

all the way.

• The icemaker sensor arm

is restricted or out of

position.

• Set the freezer drawer to a

colder setting.

• Make sure the water pressure

is between 25-121 psi and

add water booster if too low.

• Make sure the water valve

supply is open all the way.

• Make sure the water filter is

distributing enough water and

is not clogged.

• Make sure the drawer gaskets

are sealing and kept clean

from dirt and debris.

The

icemaker

runs

continuously.

• The icemaker level sensor

is stuck in the down

position.

• Check the movement of the

icemaker sensor arm so it rests

in the “up” position.

• Make sure no frozen packs or

objects are obstructing the

icemaker sensor arm.