Installation, Minimum alcove clearance to combustible materials, Additional clearances for backwall exit – Hampton Direct H200 User Manual

Page 10

Advertising
background image

Hampton H200 Cast Freestanding Woodstove

10

MINIMUM ALCOVE CLEARANCE TO

COMBUSTIBLE MATERIALS

This Hampton Freestanding model has been alcove approved and must be installed
with a listed double wall connector to the ceiling level.

Note: Minimum alcove ceiling height (from fi nished fl oor) - 60" (1525 mm)

Maximum depth of alcove - 48" (1220 mm)

INSTALLATION

From From Flue Min. Min.Hearth

Unit (with Heat Shield)

Unit

Center-line Width to Rear Wall

G H

I J K L

H200 15" (381 mm) 13" (330 mm) 27" (686 mm) 15-1/8" (384 mm) 54" (1372 mm) 50" (1270 mm)

ADDITIONAL CLEARANCES

FOR BACKWALL EXIT

From

Unit (with Heat Shield)

Unit

A B


H200
9" (228 mm) 15" (381 mm)

Note: Floor Protection must extend 2" (50mm)

to each side of the elbow.

Minimum Clearance to Combustibles

Minimum Clearance to Non-Combustibles

From

Unit (with Heat Shield)

Unit

A B

H200 min. 0" (0 mm) 15" (381 mm)

max. 9" (228 mm)

Min. Mantel Height (from fi nished fl oor):

48" (1219 mm)

Max. Mantel Depth: 12"

(305

mm)