Output sequence editor, Require output sequence, Output sequence editor require output sequence – Hand Held Products 2D IMAGER 4800P User Manual

Page 38

Advertising
background image

3 - 10

4800p 2D Imager User’s Guide

41

start character match for Code 39, 41h = “A”

FF

termination string for first code

6A

code identifier for Code 128

0013

B - Code 128 sample length (12) plus CR suffix (1) = 13

42

start character match for Code 128, 42h = “B”

FF

termination string for second code

69

code identifier for Code 93

0012

C - Code 93 sample length (11) plus CR suffix (1) = 12

43

start character match for Code 93, 43h = “C”

FF

termination string for third code

Output Sequence Editor

Require Output Sequence

When an output sequence is

Required, all output data must conform to an edited

sequence or the imager will not transmit the output data to the host device.
When it’s

On/Not Required, the imager will attempt to get the output data to

conform to an edited sequence, but if it cannot, the imager transmits all output
data to the host device as is.

When the output sequence is

Off, the bar code data is output to the host as the

imager decodes it.

Note: This selection is unavailable when the Multiple Symbols Selection is

turned on.

Enter Sequence

Default Sequence

Required

On/Not Required

*Off