Clearances to Combustibles:
Refer to Section 5 for clearances to the appliance, man-

tel, mantel legs and wall projection.
Refer to Section 8 for pipe clearances to combustibles.
Termination Cap
For installation of termination cap see minimum vent

heights for various pitched roofs. See Section 6 of appli-

ance owner’s manual.
Flue Damper
Fully lock the solid fuel fi replace’s fl ue damper in the open

position, OR completely remove it.
Venting Components
The LINK-DV30B is approved for use with the coaxial/co-

linear venting application. The LINK-DV30B kit includes:
• Two 30 feet sections of fl exible vent pipe (3 inches Ø).

One section is used to draw combustion air and the other

section is used to expel exhaust gases.

• One vertical termination cap.

WARNING! Risk of Fire! Coaxial to colinear venting

confi guration may only be used in existing non-combus-

tible chimney. Installation in any other venting application

could cause fi re.
Prior to installing the gas appliance:
• Have the chimney and adjacent structure inspected

and cleaned by qualifi ed professionals. Hearth & Home

Technologies recommends that NFI or CSIA certifi ed

professionals, or technicians under the direction of certi-

fi ed professionals, conduct a minimum of a NFPA 211

Level 2 inspection of the chimney.

• Replace component parts of the chimney and fi replace

as specifi ed by the professionals.

• Ensure all joints are properly engaged and the chimney

is properly secured.

EXHAUST VENT PIPE

INLET AIR VENT PIPE

Figure 7.14 Coaxial/Colinear Appliance Adapter (DV-46DVA-GCL)

Coaxial to Colinear Venting

The coaxial to colinear adapter (DV-46DVA-GCL) is ap-

proved for installations into solid fuel masonry or factory

built fi replaces that have been installed in accordance

with the National, Provincial, State and local building

codes. The DV-46DVA-GCL must be recessed into exist-

ing masonry fi replace. See Table 1 and Figure 7.15.

OUTSIDE FACE OF

FIREPLACE

TOP OF FIREPLACE

OPENING

SHADED AREA DEFINED AS

“INSIDE EXISTING MASONRY FIREPLACE”

3 IN. MIN.

5 IN. MIN.

EXHAUST VENT PIPE

Figure 7.15 Existing Fireplace DV-46DVA-GCL Clearance

Requirements

Table 1

CLEARANCE TO COMBUSTIBLES REQUIREMENTS

DV-46DVA-GCL

3 IN.

Exhaust Vent Pipe

5 IN.

CAUTION! DO NOT use any fl ue restrictor when vent-

ing with the DV-46DVA-GCL adapter and LINK-DV30B

kit. This may result in poor fl ame appearance, sooting,

pilot malfunction, or overheating.