C. BTU Specifi cations

MODEL: SLR-B
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
Vented Gas Fireplace Heater
STANDARD:
ANSI Z21.88b-2008 CSA 2.33a-2008

Vented Gas Fireplace Heaters

This product is listed to ANSI standards for “Vented Gas

Fireplace Heaters” and applicable sections of “Gas Burn-

ing Heating Appliances for Manufactured Homes and

Recreational Vehicles”, and “Gas Fired Appliances for

Use at High Altitudes”.

Models

(U.S. or Canada)

Maximum

Input

BTU/h

Minimum

Input

BTU/h

Orifi ce

Size

(DMS)

SLR-B (NG)

US

(0-2000 FT)

26,000

N/A

#42

CANADA

(2000-4500 FT)

21,870

N/A

#43

SLR-B (LP)

US

(0-2000 FT)

25,000

N/A

.057

CANADA

(2000-4500 FT)

23,500

N/A

#54

A. Appliance Certifi cation

E. Non-Combustible Materials Specifi cation

Material which will not ignite and burn. Such materials are

those consisting entirely of steel, iron, brick, tile, concrete,

slate, glass or plasters, or any combination thereof.

Materials that are reported as passing

ASTM E 136,

Standard Test Method for Behavior of Materials in a

Vertical Tube Furnace at 750 ºC and UL763 shall be

considered non-combustible materials.

F. Combustible Materials Specifi cation

Materials made of or surfaced with wood, compressed pa-

per, plant fi bers, plastics, or other material that can ignite

and burn, whether fl ame proofed or not, or plastered or

unplastered shall be considered combustible materials.

G. Electrical Codes

NOTICE: This appliance must be electrically wired and

grounded in accordance with local codes or, in the absence

of local codes, with

National Electric Code ANSI/NFPA

70-latest edition or the Canadian Electric Code CSA

C22.1.
• A 110-120 VAC circuit for this product must be protected

with ground-fault circuit-interrupter protection, in compliance

with the applicable electrical codes, when it is installed in

locations such as in bathrooms or near sinks.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.

This appliance is tested and approved as either supplemen-

tal room heat or as a decorative appliance. It should not be

factored as primary heat in residential heating calculations.

D. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced,

these rules do not apply. Check with your local gas utility

or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet

above 2000 feet.

• In CANADA: Reduce input rate 10% for elevations

between 2000 feet and 4500 feet. Above 4500 feet,

consult local gas utility.

Check with your local gas utility to determine proper

orifi ce size.

NOTICE: This installation must conform with local codes.

In the absence of local codes you must comply with the

National Fuel Gas Code, ANSI Z223.1-latest edition in

the U.S.A. and the CAN/CGA B149 Installation Codes in

Canada.

1

Listing and Code Approvals

B. Tempered Glass Specifi cations

Hearth & Home Technologies appliances manufactured

with tempered glass may be installed in hazardous loca-

tions such as bathtub enclosures as defi ned by the Con-

sumer Product Safety Commission (CPSC). The tempered

glass has been tested and certifi ed to the requirements

of

ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing

Certifi cation Council

SGCC# 1595 and 1597. Architectur-

al Testing, Inc. Reports

02-31919.01 and 02-31917.01).

This statement is in compliance with

CPSC 16 CFR Sec-

tion 1201.5 “Certifi cation and labeling requirements”

which refers to

15 U.S. Code (USC) 2063 stating “…Such

certifi cate shall accompany the product or shall otherwise

be furnished to any distributor or retailer to whom the

product is delivered.”
Some local building codes require the use of tempered

glass with permanent marking in such locations. Glass

meeting this requirement is available from the factory.

Please contact your dealer or distributor to order.