Honeywell HZC-855PX User Manual

Page 18

Advertising
background image

- 18

-

5.11 Camera ID SET

① ID SET

: Camera ID is indicating number assigned each Camera in case of

controlling many Cameras. It is from 0 to 255. But in case of 0,

that is not displayed on screen. It is always displayed even though
whole Operating OSD is disappeared on the screen. But it is
possible to make non display and to choose display position

(BOTTOM RIGHT, TOP RIGHT, TOP LEFT) by RS-232C
communication.
CAMERA ID 0 ~ 255

caution

1. In case of Camera ID FIX model, it cannot be selected..
2. ID is not changed by MENU control through communication.

② DISPLAY MODE

: Choose which is to display Camera ID or Title.

DISPLAY CAM ID → TITLE →

….

③ DISPLAY POSITION

: Choose where is to display Camera ID or Title on Right Bottom,

Left Top, Right Top or not to display.
POSITION R.BOT → L.TOP → R.TOP → NONE

Quick setting method for Privacy Zone Masking

1. Zoom in wide as possible as you can.
2. Select Zone Number in

“ZONE NUM.”.

3. Select

“On” by push the right button.

4. Push Menu button on the

“CONTROL” to be able to move to

wanted position spot and push again to go back to main Menu.

5. Set the H and V value on the Menu.
6. Select a color.
7. Push Menu button to save the setting.

<< PRIVACY ZONE >>

ZONE NUM. ZONE1

CONTROL ON

H START 332

H END 432
V START 206

V END 286

PZM MASKING BLUE

RETURN

PRESS MENU TO MOVE

TELE: ↑, WIDE: ↓

NEAR: →, FAR: ←

RETURN MENU

<Fig 5-11. Privacy Zone Setting >

<< SETUP MENU >>

LENS MODE

AE MODE

WB MODE

NIGHTSHOT MODE
BLC/WDR MODE

PZM SETTING

CAMERA ID SETTING

SPECIAL FUNCTION

FACTORY DEFAULT

<< CAMERA ID SET >>

CAMERA ID 001

DISPLAY CAM ID

POSITION R.BOT

ABCDEFGHIJKLMNOPQRST

UVWXYZabcdefghijklmn

opqrstuvwxyz12345678

9!?#$%&<>*,.:;/+-=~

TITLE : HONEYWELL

RETURN

<Fig 5-12. CAMERA ID Setting>