44 servicing your snowblower – HONDA HS1132 User Manual

Page 46

Advertising
background image

44

SERVICING YOUR SNOWBLOWER

20°C
10°C

0°C

10°C

U

U

P

P

P

P

E

E

R

R

L

L

I

I

M

M

I

I

T

T

L

L

O

O

W

W

E

E

R

R

L

L

I

I

M

M

I

I

T

T

If the fluid level is low, add Honda Hydrostatic Fluid.

The use of other hydrostatic fluids will reduce transmission
performance and may damage the transmission. Use only Honda
Hydrostatic Fluid.

Unscrew the reservoir cap and remove the seal. Be careful to
prevent dirt, water, or snow from entering the reservoir.

Reinstall the seal, and tighten the cap securely.

Add Honda Hydrostatic Fluid to bring the fluid level to the UPPER
limit mark at room temperature, or to the appropriate level shown in
the temperature chart. Do not overfill.

1.

2.

3.

Temp

20°C

(68°F)

10°C

(50°F)

0°C

(32°F)

10°C

(14°F)

Fluid level

Between upper and lower limit marks

(approx. 5 mm (0.20 in) above lower limit marks)

Slightly above lower limit mark

(approx. 2 mm (0.08 in) above lower limit mark)

Slightly below lower limit mark

(approx. 1 mm (0.04 in) below lower limit mark)

Between lower limit mark and bottom of reservoir

(approx. 4 mm (0.16 in) below lower limit mark)

06/11/16 10:18:44 31767721_045

Advertising