KRA 405B RADAR ALTIMETER INSTALLATION MANUAL

Page 2-15

006-10536-0010 Rev. 10

Oct/2005

To program the configuration module, a KPA 900 with software 222-

00366-0002 or greater is needed (See section 1.6.

B. KPA 900

CONFIGURATION MODULE PROGRAMMER KIT

).

Follow the instructions in the KPA 900 operator’s manual (006-05392-

00XX) which is included in the KPA 900 Configuration Module

Programmer Kit to perform the programming. The KRA 405B uses a

configuration module type CM 2000 P/N 071-00093-0100.

2.6

POST INSTALLATION

A.

POST INSTALLATION CALIBRATION

The KRA 405B DOES NOT require an AID to cause the display of zero

feet while on ground. Variations in antenna cables and antenna

height are resolved during a one-time calibration procedure. The

result of the calibration is retained indefinitely internal to the

KRA 405B.

The following conditions must be met before initiating the

calibration.

1.

The KRA 405B, indicator, and antennas must be installed. The

KRA 405B, antennas, and coaxes must be mounted and routed in

the final configuration to be representative of the normal

flight conditions.

2.

The calibration must be accomplished outside of the hanger

with no obstacles surrounding or underneath the aircraft. Ex-

traneous reflections may cause an incorrect calibration.

3.

Allow a minimum of three minutes of warm-up time before ini-

tiating the calibration.

4.

Installations with dual radar altimeter system must calibrate

each side separately. The unused side must either be unplugged

or the circuit breaker disabled so as to prevent the possi-

bility of interference with the side being calibrated.

The calibration is accomplished by pressing the recessed switch (SW

1) on the front of the KRA 405B (see

FIGURE 2-4 KRA 405B POST

INSTALLATION CALIBRATION SWITCH

). Note that this switch is

intentionally difficult to press. It must be pressed through a hole

in the front panel with a tool no greater than 0.12 inches in

diameter for at least 0.2 inches. Hold the switch for at least ten

seconds to ensure that the KRA 405B accepts the switch press.