B. kni 415/416 indicator, B. kni 415/416 indicator -23 – Honeywell KA 54 User Manual

Page 49

Advertising
background image

N

KRA 405B RADAR ALTIMETER INSTALLATION MANUAL

Page 2-23

006-10536-0010 Rev. 10

Oct/2005

1.

Loosen fluted retaining screw clamp, located on

the front of the mounting rack, remove triangular

keeper from the front lip of the unit, and slide

unit out of the rack.

2.

Remove (4) #6-32 screws, securing unit to mounts,

and remove.

(2)

Re-installation

a.

For Rack Mount, follow procedure outlined in step 1,

For Shock Mount and Direct Mount, follow procedure out-

lined in step 2,

1.

Slide the unit into the rack. Hook the triangular

keeper over the front lip of the unit and tighten

the fluted retaining screw clamp located on the

front of the mounting rack until secure.

2.

Align unit with mounting holes and secure with (4)

#6-32 screws.

b.

Re-attach mating cable to Cannon connector (P4051) on

the front of the unit.

c.

Re-attach mating coaxial cables to XMIT (P4052) and RCVR

(P4053) TNC connectors on the front of the unit.

B.

KNI 415/416 INDICATOR

(refer to

FIGURE 2-5 KNI 415/416 INSTALLATION DRAWING

for details)

(1)

Removal

a.

Detach mating cable from Cannon connector (P4151/P4161)

on the back of the unit.

b.

Remove (4) #6-32 screws, securing unit to panel. Unit

may be front or rear mounted relative to panel.

(2)

Re-installation

a.

Align unit with panel mounting holes and secure with (4)

#6-32 screws. Unit may be front or rear mounted rela-

tive to panel.

Advertising