KRA 405B RADAR ALTIMETER INSTALLATION MANUAL

Page 2-20

006-10536-0010 Rev. 10

Oct/2005

An antenna fault will be detected when its cable is ter-

minated into a 50 ohm load and the indicator needle will

stow behind the mask. Re-bond the antenna if the point-

er is now stowed.

If the indicator pointer still does not stow, this in-

dicates an RF cable or connector problem. Remove both

cables at the antenna and terminate one of them with a

50 ohm RF load. Remove the other cable at the R/T end

and terminate with a 50 ohm RF load. The indicator nee-

dle should stow behind the mask.

h.

Repeat this test for the other cable. A fault here can

be addressed by following the suggestions in

2.5 KRA

405B SYSTEM INSTALLATION

pertaining to the cables.

D.

TEST PROCEDURE

KRA 405B Radar Altimeter Post Installation Test Procedures using

1000 Foot Delay Line.

(1)

Purpose of Test.

This test simulates an actual altitude of 1000 feet AGL with

various return signal strengths. Low power output, poor coax

cables, poor connectors and poor R/T performance can be found

using this method.

(2)

Required Equipment

The items listed below or their electrical equivalent, may be

used to conduct the tests in this section.

QUANTITY

DESCRIPTION

MANUFACTURER

MANU. PART NUMBER

1

1000 ft Delayline

Teledyne

M7421B

1

Attenuator Variable

4-8 GHz 0-40 dB

Narda

794-FM

2

Attenuator Fixed

3-6 GHz 20 dB

Narda

773-20

2

Adapter N

F

to SMA

P/N 030-00123-0000

Americon

2082-2300

2

Adapter N

M

to TNC

F

Amphenol

78800

1

Adapter N

M

to TNC

M

Amphenol

78875

1

6 ft RG 393/U with TNC

M

con-

nector