Quickspecs, Hp proliant bl25p server blade – HP 275 User Manual

Page 13

Advertising
background image

HP BladeSystem

HP BladeSystem

HP BladeSystem

HP BladeSystem
p-Class Power System

p-Class Power System

p-Class Power System

p-Class Power System
and Rack Information

and Rack Information

and Rack Information

and Rack Information

NOTE:

NOTE:

NOTE:

NOTE: To determine power configuration please refer to the HP BladeSystem p-Class Overview and
Planning Whitepaper and sizing tool at

http://h18000.www1.hp.com/products/servers/proliant-bl/p-

class/20p/index.html

.

HP BladeSystem

HP BladeSystem

HP BladeSystem

HP BladeSystem
p-Class 3U Power

p-Class 3U Power

p-Class 3U Power

p-Class 3U Power
Enclosure

Enclosure

Enclosure

Enclosure

3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Dual input single
phase and three phase models available.

HP BladeSystem p-Class 3U power enclosure provides external, shared hot-plug power. Each three-
phase power enclosure houses up to six hot-plug power supplies each single-phase power enclosures
hold up to four hot-plug power supplies to power the BL p-Class server blades and interconnects
Please use the sizing utility to determine the power needed for each configuration

http://www.hp.com/go/bladesystem/powercalculator

.

Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using
facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed.

HP BladeSystem

HP BladeSystem

HP BladeSystem

HP BladeSystem
p-Class 1U Power

p-Class 1U Power

p-Class 1U Power

p-Class 1U Power
Enclosure

Enclosure

Enclosure

Enclosure

1U (1.75-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Multi-input single
phase or three phase operation.
HP BladeSystem p-Class 1U power enclosure provides external, hot-plug power. Each 1U power
enclosure houses up to six hot-plug power supplies to power up to one server blade enclosure, fully
populated with BL p-Class server blades and interconnects.
Please use the sizing utility to determine the power needed for each configuration

http://www.hp.com/go/bladesystem/powercalculator.

NOTE: Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If
using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed.

HP BladeSystem

HP BladeSystem

HP BladeSystem

HP BladeSystem
p-Class Power

p-Class Power

p-Class Power

p-Class Power
Distribution (only required

Distribution (only required

Distribution (only required

Distribution (only required
with 3U power

with 3U power

with 3U power

with 3U power
enclosures)

enclosures)

enclosures)

enclosures)

In the HP BladeSystem p-Class infrastructure, redundant -48 VDC power (from the power enclosures or
facility DC power) is distributed from the power enclosures to the server blade enclosures through the bus
bar system. Hinges attach the HP BladeSystem bus bars to the rails in a rack. The bus bars swing open
from the center to enable easy rear access to the server blades and network cables. Power is distributed
redundantly through independent A- and B-sided bus bars.
Three different power distribution solutions are available depending on the maximum number of server
blade enclosures planned for the rack:

HP BladeSystem p-Class scalable bus bar
HP BladeSystem p-Class mini bus bar
HP BladeSystem p-Class power bus box

NOTE:

NOTE:

NOTE:

NOTE: To support a full 42U rack of HP ProLiant BL25p server blades (6 server blade enclosures), two
mini bus bars are needed.