Introducing the ProCurve 620 Redundant and External Power Supply
Back of the Unit

Introducing the ProCurv

e

620

Redu

nda

nt an

d Ex

ternal

Pow

e

r

Back of the Unit

Figure 1-3. Back of 620 RPS/EPS

RPS Ports on the 620 RPS/EPS

The 620 RPS/EPS has two redundant power supply ports. You can connect up
to two ProCurve switch units, and backup power can be supplied to up to two
units.

EPS Ports on the 620 RPS/EPS

The 620 RPS/EPS has two external power supply ports. You can connect one
or two ProCurve PoE capable switches to provide PoE power as a primary or
backup source. Each port receives the maximum power (398 W). Each EPS
port is independent of the other. Therefore if one fails the other can still
provide EPS power.

Port Status LEDs

The RPS and EPS port status LEDs on the 620 RPS/EPS back panel are a
duplication of those on the front panel. For a description of these LEDs, see

Table 1-1 on page 1-2

.

Power Connector

The 620 RPS/EPS does not have a power switch; it is powered on when
connected to an active AC power source. The 620 RPS/EPS automatically
adjusts to any voltage between 100-127 and 200-240 volts and either 50 or 60
Hz. There are no voltage range settings required.

RPS ports

EPS ports

RPS port LEDs

EPS port LEDs

AC power

connector