Introducing the ProCurve 620 Redundant and External Power Supply
Front of the Unit

Introducing the ProCurv

e

620

Redu

nda

nt an

d Ex

ternal

Pow

e

r

Front of the Unit

Figure 1-2. Front of 620 RPS/EPS

LEDs

RPS port LEDs

Fan and Temp

Status LED

EPS port LEDs

Device Connected

Power

and Fault

LEDs

Power Status

Table 1-1.

620 RPS/EPS LEDs

LED

State

Meaning

Power
(green)

On

The unit is powered on.

Off

The unit is NOT powered on.

Fault
(orange)

Off

The normal state; indicates that there are no fault conditions on the unit.

Blink
orange

1, 3

A fault has occurred on the unit, one of the ports, or the fan. The Status LED for the
component with the fault will blink simultaneously.

On

On briefly after the unit is powered on or reset. If this LED is on for a prolonged
time, the unit has encountered a fatal hardware failure. See chapter 3,

“Troubleshooting”

for more information.

Temp Status
(green and
orange)

On (green)

The cooling fans are operating normally.

Blink
orange

2

One of these conditions exists:
• A cooling fan has failed. The unit Fault LED and Fan Status LED will be blinking

simultaneously.

• There is an over temperature condition in the unit. The unit Fault LED is off.

Fan Status
(green and
orange)

On (green)

The cooling fans are operating normally.

Blink
orange

1

A cooling fan has failed. The unit Fault LED will be blinking simultaneously.

Port Status (also on back panel of the 620 RPS/EPS)