General information, Model onrb – Hill Phoenix ORB User Manual

Page 10

Advertising
background image

6

C

L

NOTES:

* STUB-UP AREA
** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS

z

ENDS ADD APPROXIMATELY 1 INCH TO CASE HEIGHT

z

WIRING-TO-THE-TOP- ADDS APPROXIMATELY 1 INCH TO CASE HEIGHT

z

A 2" MINIMUM AIR GAP IS REQUIRED BETWEEN THE REAR OF THE CASE AND A WALL

z

SUCTION LINE (ALL LENGTHS) 1/2"

z

LIQUID LINE (ALL LENGTHS) - 3/8", LIQUID LINE w/ HOT GAS DEFROST (ALL LENGTHS) - 1/2"

z

AVAILABLE SHELF SIZES: WIRE SHELVES 16", 18", 20" & 22"

SOLID SHELVES 18", 20" & 22"
(TOP SHELF MUST BE 20" OR SHORTER. RECOMMENDED CONFIGURATION IS 20"
SHELF AND 4 22" SHELVES BELOW TOP SHELF)

JUNCTION BOX

(STANDARD)

WIRING-TO-TOP
(OPTIONAL)

ELECTRICAL

1 1/2" PVC DRAIN
CONNECTION

REFRIGERATION

FRONT OF CASE

10 in

[25.4 cm]

8 in [20.3 cm]

16 1/16 in [40.8 cm]

18 9/16 in [47.1 cm]

27 9/16 in

[70.0 cm]

**

23 1/4 in
[59.1 cm]

26 7/8 in
[68.3 cm]

1 1/2 in [3.8 cm]

{END}

8 11/16 in [22.1 cm]

COIL

PLENUM

23 1/4 in

[59.1 cm]

6 13/16 in [17.3 cm]*

24 3/16 in

[61.4 cm]

31 7/8 in

[81.0 cm]

35 3/8 in [89.8 cm]

5 1/8 in

[13.1 cm]

16 1/4 in

[41.3 cm]

8 in

[20.3 cm]

64 in

[162.6 cm]

(Frame Height)

62 3/8 in

[158.4 cm]

(Door Height)

59 in

[149.9 cm]

24 3/16 in [61.4 cm]

31 7/8 in [81.0 cm]

27 5/16 in

[69.4 cm]

REAR REFRIGERATION
(12 1/4" off of floor)

4 in

[10.2 cm]

PIPING-TO-TOP
(OPTIONAL)

3 3/8 in [8.6 cm]

12 3/4 in [32.4 cm]

60 in [152.4 cm] {2 Door}
90 in [228.6 cm] {3 Door}

120 in [304.8 cm] {4 Door}
150 in [381.0 cm] {5 Door}

81 1/4 in

[206.4 cm]

83 1/4 in

[211.5 cm]

34 5/8 in [88.0 cm]

7 1/2 in

[19.1 cm]

1/2 BUMPER OPTION

35 3/8 in

[89.8 cm]

MODEL

ONRB

Amp plate &
Serial Plate
location

GENERAL INFORMATION

Advertising