Case operation, Narrow glass door reach-in beverage merchandiser, Defrost controls – Hill Phoenix ORB User Manual

Page 32: Lighting data, Electrical data, Guidelines & control settings, Onrb - 2, 3, 4 & 5-door

Advertising
background image

28

CASE OPERATION

1

Not applicable.

All measurements are taken per ARI 1200 - 2002 specifications.

Medium Temperature Defrost Schedule

No. Per Day

Hours

1

12 midnight

2

12 am - 12 pm

3

6 am - 2 pm - 10 pm

4

12 - 6 am - 12 - 6 pm

6

If timed off defrost is utilized. If electric or hot gas defrost is utilized case only requires 1 defrost per day.

7

NOTE: - - - not an option on this case model.

Electric Defrost

Defrosts

Per Day

4

6

Model

ONRB

Fail-safe

(min)

30

Termination

Temp. (°F)

47

Defrost Controls

Timed Off Defrost

Fail-safe

(min)

30

Termination

Temp. (°F)

40

Hot Gas Defrost

Fail-safe

(min)

24

Termination

Temp. (°F)

47

Reverse Air Defrost

Fail-safe

(min)

- - -

7

Termination

Temp. (°F)

- - -

Run-Off

Time (min)

6 - 8

Maximum

Lighting

120 Volts

Amps

1.50

1.90

2.40

2.90

Watts

180

228

288

348

Typical per

Light Row

120 Volts

Amps

NA

1

NA

NA

NA

Watts

NA

NA

NA

NA

Lighting Data

2-door

3-door

4-door

5-door

ONRB

Model

2-door

3-door

4-door

5-door

Standard Fans

Amps

1.00

1.50

2.00

2.50

Watts

60

90

120

150

Defrost Heaters

208 Volts

Amps

4.39

4.96

6.51

7.96

Watts

914

1032

1355

1655

240 Volts

Amps

5.06

5.71

7.55

9.17

Watts

1215

1370

1813

2201

Anti-Condensate

Heaters

120 Volts

Amps

1.01

1.49

1.96

2.40

Watts

121

179

235

288

Fans per

Case

2

3

4

5

High Efficiency

Fans

120 Volts

Amps

0.31

0.46

0.61

0.77

Watts

18.4

27.6

36.8

46.0

Electrical Data

ONRB

Model

120 Volts

COMPONENT

Guidelines & Control Settings

2

All data listed is for an ONRB configured with 20” shelves.

3

BTUHs/door listed are for parallel operation. Conventional ratings may be approximated by multiplying listed rating by 1.04.

4

High efficiency fans reduce refrigeration load by 96 BTUHs/fan.

5

Average discharge air velocity at peak of defrost.

830

4

800

4

BTUH/door

3

Model

32

34

Evaporator

(°F)

36

38

38

40

Return Air

(°F)

460

460

Discharge Air Velocity

5

(FPM)

Discharge Air

(°F)

ONRB

2

-

Deli/Dairy

ONRB

2

-

Beverage

Superheat Set

Point @ Bulb (

o

F)

6-8

6-8

Enh.

Enh.

Coil

Type

Narrow Glass Door Reach-in Beverage Merchandiser

ONRB - 2, 3, 4 & 5-door

Advertising
This manual is related to the following products: