Lighting data, Electrical data, Defrost controls – Hill Phoenix ORB User Manual

Page 33: Guidelines & control settings, Onrbh - 2, 3, 4 & 5-door

Advertising
background image

29

1

Not applicable.

All measurements are taken per ARI 1200 - 2002 specifications.

Medium Temperature Defrost Schedule

No. Per Day

Hours

1

12 midnight

2

12 am - 12 pm

3

6 am - 2 pm - 10 pm

4

12 - 6 am - 12 - 6 pm

Maximum

Lighting

120 Volts

Amps

1.50

1.90

2.40

2.90

Watts

180

228

288

348

Typical per

Light Row

120 Volts

Amps

NA

1

NA

NA

NA

Watts

NA

NA

NA

NA

Lighting Data

2-door

3-door

4-door

5-door

ONRBH

Model

2-door

3-door

4-door

5-door

Standard Fans

Amps

1.00

1.50

2.00

2.50

Watts

60

90

120

150

Defrost Heaters

208 Volts

Amps

4.39

4.96

6.51

7.96

Watts

914

1032

1355

1655

240 Volts

Amps

5.06

5.71

7.55

9.17

Watts

1215

1370

1813

2201

Anti-Condensate

Heaters

120 Volts

Amps

1.06

1.55

2.07

2.54

Watts

127

186

248

305

Fans per

Case

2

3

4

5

High Efficiency

Fans

120 Volts

Amps

0.31

0.46

0.61

0.77

Watts

18.4

27.6

36.8

46.0

Electrical Data

ONRBH

Model

120 Volts

COMPONENT

6

If timed off defrost is utilized. If electric or hot gas defrost is utilized case only requires 1 defrost per day.

7

NOTE: - - - not an option on this case model.

Electric Defrost

Defrosts

Per Day

4

6

Model

ONRBH

Fail-safe

(min)

30

Termination

Temp. (°F)

47

Defrost Controls

Timed Off Defrost

Fail-safe

(min)

30

Termination

Temp. (°F)

40

Hot Gas Defrost

Fail-safe

(min)

24

Termination

Temp. (°F)

47

Reverse Air Defrost

Fail-safe

(min)

- - -

7

Termination

Temp. (°F)

- - -

Run-Off

Time (min)

6 - 8

Guidelines & Control Settings

2

All data listed is for an ONRBH configured with 20” shelves.

3

BTUHs/door listed are for parallel operation. Conventional ratings may be approximated by multiplying listed rating by 1.04.

4

High efficiency fans reduce refrigeration load by 96 BTUHs/fan.

5

Average discharge air velocity at peak of defrost.

830

4

800

4

BTUH/door

3

Model

32

34

Evaporator

(°F)

36

38

38

40

Return Air

(°F)

405

405

Discharge Air Velocity

5

(FPM)

Discharge Air

(°F)

ONRBH

2

-

Deli/Dairy

ONRBH

2

-

Beverage

Superheat Set

Point @ Bulb (

o

F)

6-8

6-8

Enh.

Enh.

Coil

Type

High Narrow Glass Door Reach-in Beverage Merchandiser

ONRBH - 2, 3, 4 & 5-door