Electrical wiring, Service instructions, A. replacing the light bulb – Hearth and Home Technologies SIMPLIFYRE SFE-35 User Manual

Page 7: B. screen cleaning, C. maintenance of motors, D. resetting the temperature cutout switch

Advertising
background image

7

Hearth & Home Technologies Inc. • SFE-35 • 4050-313 Rev C • 01/08

4

Electrical Wiring

Projector

Lamp

S7

X1

Motor

Interlock on

Media Cabinet only

Power Supply Module

Hot Line

Ground

Neutral

Branch Circuit

12 VOC

Power

Supply

Heater

Motor

Hi Limit

Heater-Blower

Heat Indicator

LED LED LED

LED LED LED

Ember Bed & Back Log

4050-310

Wall Thermostat

4050-309

Wall Switch

Flame

Heat

Terminal Strip

ON

RD

WH

WH

RD

Remote Receiver

Flame

Heat

NEMA-5 IEC 320 C13/C14

M

M

P1

1

5

R2

R1

D1

J1

5

Service Instructions

A. Replacing the Light Bulb

This appliance uses a single 12 Volt, 35 Watt, MR-16 bulb.

The bulb is located behind the smoke shield.
A spare is provided with the unit. Replacement bulbs

(Part No. 4050-123) are available through your Simplifyre

dealer.
• Turn off power to the unit at the main service panel.

• Let the fi replace cool if it has been operating.

• Release the spring pins and remove the upper shield.

• Remove the two screws on the projector basket.

• Rotate the housing down to access the bulb.

• Remove the screws holding the bulb and socket.

• Unplug the bulb from the socket.

• Replace the bulb.

• Re-assemble in the reverse order.

B. Screen Cleaning

During shipment, installation, handling, etc., the screen

surface may collect dust particles; these can be removed

by lightly wiping with a clean, dry cloth.

C. Maintenance of Motors

The motors used on the fan and fl ame projector assembly

are pre-lubricated for extended bearing life and require no

further lubrication. However, periodic cleaning/vacuuming

of the fan/heater unit is recommended.

D. Resetting the Temperature Cutout Switch

The heater on this fi replace is protected with a safety device

to prevent overheating. Should the heater overheat, an

automatic cutout will turn OFF the heater/blower. The switch

is reset by turning the unit OFF, waiting 10-15 minutes and

switching the unit back ON.

WARNING! Disconnect power at circuit breaker before

attempting any maintenance or cleaning to reduce the

risk of fi re, electrical shock or personal injury.