Hearth and Home Technologies SIMPLIFYRE SFE-35 User Manual

Page 8

Advertising
background image

8

Hearth & Home Technologies Inc. • SFE-35 • 4050-313 Rev C • 01/08

E. Optional Wall Switch / Thermostat Wiring

Connections instructions

The optional wall switch and thermostat wiring is low voltage

and must be separated from power wiring. Do not connect

the switches or thermostat to house power.

To control fl ames/ember bed with a switch, and

control the heater with a thermostat:

• Switch 1 - turns fl ames/ember bed ON/OFF

• Switch 2 - turns front embers ON/OFF indicating the

heater/fan is being controlled by the thermostat (UL

requirement)

• Thermostat turns heater/fan ON/OFF as room temperature

requires it

• Switch 1 between terminal 1 and 2

• Switch 2 between terminal 1 and 3

• Thermostat between terminal 4 and 5

To control fl ames/ember bed with one switch and

heater/front embers with another switch:

• Switch 1 - turns fl ames/ember bed ON/OFF

• Switch 2 - turns heater/front embers ON/OFF

• Switch 1 between terminal 1 and 2

• Switch 2 between terminal 1 and 3

• Jumper wire between terminal 4 and 5

To control the fi replace with a single switch:

(fl ames/ember bed and heater/front embers all on or all off)

• Switch between terminal 1 and 2

• Jumper wire between terminal 2 and 3

• Jumper wire between terminal 4 and 5