Quickspecs, Hp bladesystem bc1500 blade pc – HP BC1500 User Manual

Page 11

Advertising
background image

Broadcom 5705F 10/100

Broadcom 5705F 10/100

Broadcom 5705F 10/100

Broadcom 5705F 10/100
Integrated NIC

Integrated NIC

Integrated NIC

Integrated NIC

Network interface

Network interface

Network interface

Network interface

10Base-T/100Base-TX

Compatibility

Compatibility

Compatibility

Compatibility

IEEE 802.3/802.3u compliant

Data transfer method

Data transfer method

Data transfer method

Data transfer method

32-bit bus-master PCI

Features

Features

Features

Features

NIC A WOL enabled and PXE compliant

Network transfer rate

Network transfer rate

Network transfer rate

Network transfer rate

10Base-T (half-duplex)

10 Mb/s

10Base-T (full-duplex)

20 Mb/s

100Base-TX (half-duplex) 100 Mb/s
100Base-TX (full-duplex)

200 Mb/s

Connector

Connector

Connector

Connector

Mates into enclosure center wall assembly

Enclosure

Enclosure

Enclosure

Enclosure

Dimensions

Dimensions

Dimensions

Dimensions

Height

Height

Height

Height (3U)

5.25 in (13.34 cm)

Width

Width

Width

Width

19 in (48.26 cm)

Depth

Depth

Depth

Depth

27 in (68.58 cm)

Weight

Weight

Weight

Weight (with interconnect
tray)

No blade PCs

No blade PCs

No blade PCs

No blade PCs

59 lb (26.76 kg)

20 blade PCs

20 blade PCs

20 blade PCs

20 blade PCs

103 lb (46.7 kg)

Rated input

Rated input

Rated input

Rated input (autosensing) Voltage

Voltage

Voltage

Voltage

Minimum: 90 VAC
Maximum: 264 VAC
Nominal: 100 to 120 VAC or 200 to 240 VAC

Frequency

Frequency

Frequency

Frequency

47 to 63 Hz

Current

Current

Current

Current

11.7 A at 90 VAC
8.5 A at 120 VAC
4.3 A at 240 VAC

Power

Power

Power

Power

1000 W

BTUs

BTUs

BTUs

BTUs

Per hour

Per hour

Per hour

Per hour

3416

Temperature

Temperature

Temperature

Temperature

1

Operating

Operating

Operating

Operating

50° to 95° F (10° to 35° C)

Shipping, 72 hours

Shipping, 72 hours

Shipping, 72 hours

Shipping, 72 hours

-40° to 140° F (-40° to 60° C)

Relative humidity

Relative humidity

Relative humidity

Relative humidity (non-
condensing)

Operating

Operating

Operating

Operating

10% to 90%

Non-operating

Non-operating

Non-operating

Non-operating

10% to 95%

Management

Management

Management

Management

Enclosure self recovery
Health logs
Redundant power supply utility
Automatic System Recovery (ASR)

High availability

High availability

High availability

High availability

Redundant hot-plug power supplies
Redundant hot-plug fans

NOTE 1:

NOTE 1:

NOTE 1:

NOTE 1: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Storage
maximum humidity of 95% is based on a maximum temperature of 112° F (45° C). Minimum pressure for storage is 70 KPa.
For more information on CCI power and thermal facility site planning:

http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls