Quickspecs, Hp bladesystem bc1500 blade pc – HP BC1500 User Manual

Page 12

Advertising
background image

Enclosure Hot-Plug Power

Enclosure Hot-Plug Power

Enclosure Hot-Plug Power

Enclosure Hot-Plug Power
Supply

Supply

Supply

Supply

Dimensions

Dimensions

Dimensions

Dimensions

Height

Height

Height

Height

3.579 in (9.14 cm)

Depth

Depth

Depth

Depth

10.24 in (28.45 cm)

Width

Width

Width

Width

4.47 in (11.43 cm)

Weight

Weight

Weight

Weight

6.5 lb (2.95 kg)

Rated input

Rated input

Rated input

Rated input

Voltage

Voltage

Voltage

Voltage (autosensing)

100 to 127 VAC (200 to 240 VAC)

Frequency

Frequency

Frequency

Frequency

47 to 63 Hz

Current

Current

Current

Current

8.5 A at 120 VAC (4.3 A at 240 VAC)

Power

Power

Power

Power

1000 W

Maximum peak power

Maximum peak power

Maximum peak power

Maximum peak power

1167 W

Rated output

Rated output

Rated output

Rated output

Voltage/current

Voltage/current

Voltage/current

Voltage/current

5.01 V - 0.5 A ~ 34 A
3.33 V - 0.5 A ~ 36 A

12.1 V - 0.5 A ~ 38 A
5 Vaux - 0.2 A ~ 8 A

Power RMS

Power RMS

Power RMS

Power RMS

600 W

Maximum peak power

Maximum peak power

Maximum peak power

Maximum peak power

700 W for 2 minutes

Temperature

Temperature

Temperature

Temperature

1

Operating

Operating

Operating

Operating

50° to 55° F (10° to 35° C)

Non-operating, shipping

Non-operating, shipping

Non-operating, shipping

Non-operating, shipping -40° to 85° F (-40° to 60° C)

Relative humidity

Relative humidity

Relative humidity

Relative humidity

1

(non-

condensing)

Operating

Operating

Operating

Operating

10% to 90%

Non-operating

Non-operating

Non-operating

Non-operating

10% to 95%

Dieletric voltage

Dieletric voltage

Dieletric voltage

Dieletric voltage
withstand

withstand

withstand

withstand

Input to output

Input to output

Input to output

Input to output

2000 VAC minimum

Input to ground

Input to ground

Input to ground

Input to ground

1500 VAC minimum

NOTE 1:

NOTE 1:

NOTE 1:

NOTE 1: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Storage
maximum humidity of 95% is based on a maximum temperature of 112° F (45° C). Minimum pressure for storage is 70 KPa.

HP BladeSystem PC Blade

HP BladeSystem PC Blade

HP BladeSystem PC Blade

HP BladeSystem PC Blade
Switch

Switch

Switch

Switch

Port configuration

Port configuration

Port configuration

Port configuration

42 10/100BASE-T ports
4 RJ-45 10/100/1000BASE-T ports
4 SFP slots for fiber media support (disables Copper)
802.3u and 802.3ab Auto-negotiation for speed, duplex mode and
802.3x flow control; Auto MDI/MDIX on uplink ports
Port mirroring; Broadcast storm control; Cable Tester

Performance

Performance

Performance

Performance

Switching capacity 12.8 Gbps
Forwarding rate 9.5 Mpps
Up to 8,000 MAC addresses

Management

Management

Management

Management

Web-based management interface
Industry-standard CLI accessible via Telnet or Local Serial Port
SNMPv1, SNMPv2c and SNMPv3 supported; four RMON groups
supported
(history, statistics, alarms and events)
TFTP transfers of firmware and configuration files
Dual firmware images on-board
Multiple configuration file upload/download supported
Statistics for error monitoring and performance optimization including
port summary tables
DHCP IP address management supported
Secure Telnet (SSH)

QuickSpecs

HP BladeSystem bc1500 Blade PC

HP BladeSystem bc1500 Blade PC

HP BladeSystem bc1500 Blade PC

HP BladeSystem bc1500 Blade PC

Technical Specifications

DA - 12390 North America — Version 4 — January 22, 2007

Page 12

Advertising