Bolt the auto-

matic draft control to

the bottom door. Be

sure to hold the unit

straight while tighten-

ing. After the auto-

matic draft control

is mounted, the two

wires must be strung

through the flexible

conduit and two fittings

supplied. The knockout

plug of the junction box

must be removed to in-

stall the conduit fitting.

Check the door of the

automatic draft control to assure proper operation.

warning:

Keep pieces of wood or coal out of the

draft door opening mechanism, as this could cause

the door to stick.

NOTE: Oil the hinge at the begining of the heating

season with a light oil.

The junction box is best mounted on the side

of the furnace about  in. back and 8 in. from the top

of the sheet metal side. (fig. C or D) If this location is

inconvenient, anywhere on the right side will work.

SF1500, SF2500, SF3500.

This figure represents the models; SF1500,

SF500, and SF3500. It’s intention is to represent

the approximate location of the various controls.

This drawing may also be used as a recommenda-

tion for routing of the

wiring and approxi-

mate dimension of

control spacing.

Please note

that this drawing is for

reference only. Each

specific installation will

vary.

Furnace Installation

Installing wood/Coal high limit Switch-

SF600 only.

First, install the sheet metal sides as de-

scribed in the previous section. Install the snap disc

switch into the hole on the right side sheet metal.

Then mount the open backed junction box around

the snap switch. Proceed with wiring as shown on

page 0. Also refer to Figure D. in this section.

mounting The Oil burner-

SF600 only.

Remove oil burner unit from it’s box. Loosen

the four bolts in the pipe on the front of the furnace.

Insert the nose of the oil gun into the pipe. Before

sliding the oil burner all the way in, apply the gasket

around the nose of the oil gun by wrapping it around

the nose. Next, slide the oil burner into the pipe and

secure it by tightening the four bolts around the col-

lar. Be sure to tighten the bolts evenly to locate the

oil burner in the center of the pipe. The final set-up

of the oil burner should be done by an experienced

oil burner technician with the proper equipment. Re-

fer to the SF600 wiring diagram on page 0 and the

oil burner manual for proper burner set-up. There is

also a section at the end of this manual with specific

oil burner instructions.

venting guidelines.

Your Harman hot-air furnace must be vented

to it’s own separate flue-lined “Class A” chimney,

not less than 8” X 8” in size. The chimney must be

capable of providing a draft reading of at least .06”

water column on a draft meter, in order to function

properly. The Chimney must be a minimum of 6

ft. high, and must be two feet higher than anything

within 0 ft. The chimney must also be at least 3 ft.

higher than the point at which it exits or passes by

the roof. A barometric damper must be installed in

the flue to eliminate excessive draft. Any horizontal

sections of connector pipe must have at least /4 in.

per foot rise. Limit the number of elbows to two or

less. All joints in the connector pipe must be secured

with sheet metal screws.

Assembly.

Bolt the shaker handle to the block on the

lower left side of the furnace, using the bolts and

lock-washers provided.

Bolt the two manual draft controls to the

front load door. Proper installation allows the draft

controls to open approximately /” from the door

surface. See Figure .