Installation – Hatco GLO-RAY GRN User Manual

Page 16

Advertising
background image

Form No. GRM-0707

14

INSTALLATION

PERMANENT SURFACE MOUNT

Tubular Stand Mounting
Tubular stand mounting permanently attaches the
unit to a countertop or serving table. All wiring may
be concealed within the tubular stand.

Tubular stands are available in non-adjustable
heights from 10"-16" (254-406 mm) or in adjustable
heights from 10"-14" (254-356 mm).

NOTE: Tubular stands are not field retro-fittable.

NOTE: If wiring is to be concealed, a 1" (25 mm)
diameter hole must be provided in the mounting
surface, centered under the leg flange nearest the
electrical wiring hookup.

1. Position the unit upside-down on a flat surface.

2. Units for this application are supplied with the

conduit attached. Conduit should not be
removed.

3. If applicable, route flexible conduit through the

leg opening. Pull the leg up to the underside of
the warmer. (See Figure 15.)

4. Secure legs to warmer using screws supplied.

5. If applicable, route the flexible conduit through

opening in countertop.

6. Secure the legs to the mounting surface.

NOTE: The adjustable legs can be raised or lowered
by turning the locking set screw counterclockwise
one turn with an allen wrench, and then raising or
lowering the unit to the desired height and
retightening the screw. Do not loosen the screw
more than necessary.

NOTE: Two pairs of legs will be needed for
mounting dual units.

Figure 15. Tubular Stand Mounting

Locking
Screw

Covers

Adjustable
Leg

Non-Adjustable Leg

Flexible Conduit