Installation – Hatco GLO-RAY GRN User Manual

Page 18

Advertising
background image

Form No. GRM-0707

16

INSTALLATION

Figure 18. Combustible Spacing Requirements

Models

(A)

(B)

(C)

GRA &

10"

3"

1"

GRAL

(254 mm)

(76 mm)

(25 mm)

GRAH &

13-1/2"

3"

1"

GRAHL

(343 mm)

(76 mm)

(25 mm)

A

B

C

Figure 19. Non-Combustible Spacing Requirements

A

B

C

Pass Through Shelf

Back Wall

Counter

Pass Through Shelf

Back Wall

Counter

Clearance Requirements for Combustible
Surroundings

NOTE: Dual Strip Heaters are not to be installed in
combustible surroundings.

Must be a pass-through application, not allowed with

back wall installation.

Hardwired Units with Remote Switches

Dual Units with Remote Switches

Models

(A)

(B)†

(C)

GRA &

10"

N/A

3"

GRAL

(254 mm)

(76 mm)

GRAH &

11"

N/A

3"

GRAHL

(279 mm)

(76 mm)

Models

(A)

(B)

(C)

GRA &

8"

0"

0"

GRAL

(203 mm)

(0 mm)

(0 mm)

GRAH &

8"

0"

0"

GRAHL

(203 mm)

(0 mm)

(0 mm)

Models

(A)

(B)

(C)

GRA-XXD
GRAH-XXD

8"

3"

0"

GRAL-XXD

(203 mm)

(76 mm)

(0 mm)

GRAHL-XXD

Dual Units with Built-In Switches

Models

(A)

(B)†

(C)

GRA-XXD
GRAH-XXD

10"

N/A

1"

GRAL-XXD

(254 mm)

(25 mm)

GRAHL-XXD

Clearance Requirements for Non-Combustible
Surroundings

Corded Units with Built-In Switches

Hardwired Units with Built-In Switches

Models

(A)

(B)†

(C)

GRA &

8"

N/A

1"

GRAL

(203 mm)

(25 mm)

GRAH &

10"

N/A

1"

GRAHL

(254 mm)

(25 mm)

with Infinite
Heat Control
Switch or
Indicator Light

GRAH &

8"

N/A

1"

GRAHL

(203 mm)

(25 mm)

with On/Off
Toggle Switch

Advertising