H. Startup

CAUTION

1. All parts are factory-adjusted. Improper adjustments may result in failure.

2. If the unit is turned off, wait for at least 3 minutes before restarting the

icemaker to prevent damage to the Compressor.

3. To prevent damage to the Water Pump, do not leave the Control Switch in

the “SERVICE” position for extended periods of time when the Water Tank
is empty.

1) Open the Water Supply Line Shut-off Valve.

2) Remove the Louver.

3) Move the Control Switch on the Control Box to

the “ICE” position.

4) Turn on the power supply and allow the

icemaker to operate for 5 minutes to fill up the
Water Tank.

5) Move the Control Switch to the “SERVICE”

position. Move the Service Switch to the
“WASH” position.

6) Allow the icemaker to run for 5 minutes.

7) Move the Service Switch to the “DRAIN”

position.

8) Allow the icemaker to drain for 2 minutes.

9) Turn off the power supply.

10) Move the Control Switch to the “ICE” position.

11) Replace the Louver in its correct position.

12) Clean the Storage Bin using a neutral cleaner.

Rinse thoroughly after cleaning.

13) Turn on the power supply to start the automatic

icemaking process.

Fig. 6

Control Box

Control Switch

Service Switch

SER

VICE

OFF

CIRCULA

TE

ICE

DRAIN

WASH