Hoshizaki SELF-CONTAINED CRESCENT CUBER L1F015102 User Manual

Page 22

Advertising
background image

19

5) Allow the line to drain by gravity.

6) Attach compressed air or carbon dioxide supply to the potable water supply line Drain

Valve.

7) Move the Control Switch to the “ICE” position.

8) Quickly blow the potable water supply line out using compressed air or carbon dioxide.

2. Drain the potable Water Tank:

1) Move the Control Switch to the “SERVICE” position and the Service Switch to the

“DRAIN” position.

2) After 2 minutes, move the Control Switch to the “OFF” position.

3) Open the Door. Remove all ice from the Storage Bin and clean the Storage Bin.

4) Close the Door.

5) Replace the Louver in its correct position.

6) Turn off the power supply at the breaker box.

7) Close the potable water supply line Drain Valve.