18

* The Storage Bin is for ice use only. Do not store anything else in the bin.

* Keep the scoop clean. Clean it by using a neutral cleaner and rinse thoroughly.

* Clean the bin liner by using a neutral cleaner. Rinse thoroughly after cleaning.

3. Air Filter

The plastic mesh Air Filter removes dirt or dust from the air, and keeps the Condenser from
getting clogged. As the filter gets clogged, the icemaker’s performance will be reduced.
Check the filter at least twice a month. When it is clogged, use warm water and a neutral
cleaner to wash the filter.

4. Condenser

Check the Condenser once a year, and clean if required by using a brush or vacuum
cleaner. More frequent cleaning may be required depending on the location of the
icemaker.

C. Preparing the Icemaker for Long Storage

IMPORTANT

When shutting off the icemaker for an extended time, drain out all water from
the water lines and remove the ice from the Storage Bin. The Storage Bin
should be cleaned and dried. Drain the icemaker using air or carbon dioxide
to prevent damage to the water supply lines at sub-freezing temperatures.
Shut off the icemaker until the proper ambient temperature is resumed.

When the icemaker is not used for two or three days, it is sufficient to only move
the Control Switch to the “OFF” position, unless the icemaker will be at sub-freezing
temperatures.

1. Remove the water from the potable water supply line:

1) Remove the Louver if it has not already been removed.

2) Move the Control Switch on the Control Box to the “OFF” position.

3) Wait 3 minutes.

4) Close the potable water supply line Shut-off Valve and open the potable water supply

line Drain Valve. See Figs. 4 and 5.

Advertising