Honeywell Programmable Heat Pump T8011R User Manual

T8011r programmable heat pump thermostat, Mercury notice, Caution

Advertising
background image

X-XX UL

INSTALLATION INSTRUCTIONS

®U.S. Registered Trademark
Copyright © 2002 Honeywell • • All Rights Reserved

T8011R

Programmable Heat Pump Thermostat

APPLICATION

The T8011R Heat Pump Thermostat provides 24 Vac
control of a two-stage heating and one-stage cooling heat
pump system with manual changeover from heat to cool.
First stage heating and cooling cycle rates are fixed at 3
cph. Second stage heating cycle rate is selectable at
3, 4, 5, 6, 9 or 12 cph. Temperature indication can be set
for

°

F or

°

C.

The T8011R Heat Pump Thermostat is powered directly
from the system transformer. Setpoints are held perma-
nently in memory and retained during power outages.

The T8011R model includes a thermostat, wallplate and
owner’s guide. A 7 3/8 in. (188 mm) x 5 3/4 in. (146 mm)
decorator cover plate (for covering wall marks) is available
separately. Order Honeywell part no. 209649A (taupe) or
part no. 209649B (white).

MERCURY NOTICE

If this control is replacing a control that contains
mercury in a sealed tube, do not place your old
control in the trash. Dispose of it properly.

Contact your local waste management authority for
instructions regarding recycling and the proper
disposal of a control.

INSTALLATION

When Installing this Product…

1. Read these instructions carefully. Failure to follow

them could damage the product or cause a hazard-
ous condition.

2. Check the ratings given in the instructions and on

the product to make sure the product is suitable for
your application.

3. Installer must be a trained, experienced service

technician.

4. After installation is complete, check out product

operation as provided in these instructions.

CAUTION

Hazardous Voltage
Can damage heating/cooling system.
Disconnect power at furnace or main breaker/fuse
box.

Location

Install the thermostat about 5 ft (1.5m) above the floor in
an area with good air circulation at average temperature.
See Fig. 1. Do not install the thermostat where it can be
affected by:

drafts or dead spots behind doors and in corners.

hot or cold air from ducts.

radiant heat from the sun or appliances.

concealed pipes and chimneys.

unheated (uncooled) areas such as an outside wall
behind the thermostat.

Mounting Wallplate to Wall

IMPORTANT

Level for appearance only. The thermostat
functions normally even when not level.

Mount wallplate and the T8011R with the screws provided
(see Fig. 2) as follows:

1. Place the wallplate at the desired location on the

wall.

2. Pull the thermostat wire through the wallplate

entrance hole.

3. Fasten the wallplate to the wall using the anchors

and screws provided.

4. After wiring the wallplate, plug the hole with non-

flammable insulation to prevent drafts from affecting
the thermostat; see Wiring section.

Table 1. Description of T8011R Thermostat.

69-1436-1

Model

System

Changeover

System Selection

Fan Selection

Powering Method

T8011R

Heat Pump

Manual

Cool-Off-Heat-Em. Ht.

Auto-On

Hardwired