4

T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT

Mounting Thermostat To Wallplate

1. Slide SYSTEM switch to the Off position.
2. Engage the tabs at the top of the thermostat and

wallplate.

3. Swing down the thermostat and press the lower

edge of the thermostat onto the wallplate to latch.
See Fig. 6.

Fig. 6. Mounting thermostat to wallplate.

INSTALLER SETUP

Setting

°

F/

°

C Indication and Heat Cycle Rate

The following instructions provide the information neces-
sary to change the heating cycle rate to match the heating
equipment and to choose either Fahrenheit (

°

F) or Celsius

(

°

C) display.

NOTE:

All four steps must be completed to save
changes to the

°

F/

°

C indication and the heat

cycle rate.

1. Enter Installer Setup.

a.

Use

or

keys

to set the tempera-
ture setpoint to 52

°

F (11

°

C).

b.

Press the

and

keys simulta-

neously for more
than two seconds
to enter installer
setup.

c.

When released the three-digit software
revision code displayed.

d.

Press the

key.

Factory configura-
tion (FC) is
displayed
(A typical example
is shown, but
information displayed varies by model. This
information is for factory use only).

Optional System Checkout

When in steps 1c and 1d only, pressing the

key can be

used to turn heat or cool outputs on and off. Change the
SYSTEM switch setting to test heat or cool outputs. During
testing, the 5 minute minimum off time is bypassed. No
action takes place If the system switch is in the Off
position.

Examples: System setting at HEAT: If heat is on,

pressing the

key turns it off; if heat is off,

pressing the

key turns it on.

System setting at COOL: If cool is on,
pressing the

key turns it off; if cool is off,

pressing the

key turns it on.

NOTE:

In installer setup only, each press of the

key

momentarily displays 1. Each press of the

key

momentarily displays 2. When the keys are
released, these one-digit codes are no longer
displayed.

2. Setting

°

C or

°

F.

a.

Press the

key

again to display
the current setting.

b.

Press the

key to

change the

°

C or

°

F indication.

M14699

DASHED LINES INDICATE TABS
ON BACK OF THERMOSTAT

ENGAGE TABS AT TOP OF THERMOSTAT
WITH SLOTS ON MOUNTING PLATE.

PRESS LOWER EDGE OF
CASE TO LATCH.

A

B

SYSTEM

Cool Off Heat Em Ht

Auto On

FAN

Hold

Select

SYSTEM

Cool O

ff H

eat E

m Ht

Auto On

FAN

Hold

Select

EM. HT

. AUX. HT

.

PM

M12582A

SET

HT.

M12583A

M12584A

M12586A

M12587A

Advertising