T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT

5 FEET

[1.5 METERS]

YES

NO

NO

NO

M11338

Fig. 1. Typical location of thermostat.

Fig. 2. Mounting wallplate to wall.

Wiring

IMPORTANT

Use 18-gauge maximum wire for wiring the
T8011R Thermostat.

All wiring must comply with local electrical codes and
ordinances. Disconnect the power supply to prevent
electrical shock or equipment damage.

The shape of the terminals permits insertion of straight or
wraparound wiring connections; either method is accept-
able. A letter code is located near each terminal for
identification. See Fig. 3.

M12202

WALL

WALL
ANCHORS (2)

WALLPLATE

MOUNTING
SCREWS (2)

NOTE:

To ensure proper mounting of thermostat, restrict
all wiring to the shaded area in the center of the
terminals. See Fig. 4.

Refer to Fig. 5 for typical wiring hookup.

TERMINAL
SCREW

M11334A

G

C

R

Y

W1

L

W2

E

B

O

FOR STRAIGHT INSERTION
STRIP 5/16 IN. (8 MM)

FOR WRAPAROUND
STRIP 7/16 IN. (11 MM)

1

NOT ALL MODELS HAVE BOTH O AND B TERMINALS.

1

Fig. 3. Wiring connections.