Wall control - wsk300, Control specifi cations, Function - auxiliary features – Hearth and Home Technologies Multifunction Wall Control WSK300 User Manual

Page 13: Wall control, Auxiliary features

Advertising
background image

Wall Control - WSK300

Control Specifi cations

13

/&&

4(%2-/34!4

/.

0),/4

4)-%2

-/$%

!58

AUXILIARY button

Function - AUXILIARY features

Press UP or DOWN
arrow buttons to
determine desired
setting

Wall Control

First press the

!58

button multiple times

to scroll through to the desired Auxiliary
feature (A1, A2, or A3).

If desired Auxiliary selected is A1 or A2
use the UP or DOWN

arrow to step

through the following 4 levels:

Auxiliary Features

!58

The button will operate the
following 3 auxiliary features:

A1 = FAN (always room heating)

A2 = SWITCHES 110VAC, HI/MED/LOW

A3 = SWITCHES 110VAC, ON/OFF

AUXILIARY function
level indicator

Upon entering the OFF mode, all auxiliaries will be turned off with

the fi replace with the exception of A1 after leaving THERMOSTAT
mode. This mode activates a FAN cool-down feature that will
continue to operate the fan until all remaining heat has been
blown into the room.Auxiliary A1 (FAN) may not be operated in
the OFF mode, as this auxiliary is always a room-heating fan.

A1 may be operated during the ON mode as desired. During the

THERMOSTAT mode A1 (FAN) will be adjusted automatically
(between OFF, L1 and L2) based on the desired room
temperature setting. It will also perform a warm-up when entering
THERMOSTAT mode, and cool-down when the fl ame is no longer
necessary to heat the room. This allows energy to be conserved
as the fan will only operate when the fi replace is warm.

&! .

Auxiliaries A2 and A3 may

be adjusted in any of the
3 modes. When the ON or
THERMOSTAT mode is active
these settings will be saved
to memory and set back to
the desired levels when ON
or THERMOSTAT mode is
activated again.

OFF

L1 = Low

L2 = Medium

L3 = High