Troubleshooting – Hearth and Home Technologies Multifunction Wall Control WSK300 User Manual

Page 15

Advertising
background image

15

TROUBLESHOOTING

The operating characteristics of your fi replace may vary during a power failure or power outage. the options listed below
will help determine the current state of your system.

Condition (at time of power failure)

Result

Wall switch is in THERMOSTAT mode
with the main fl ame on and has no battery
backup or has dead batteries.

The fi replace will shut down and the display lights in the wall switch will be off. When the
power is restored to the system it will return to THERMOSTAT mode. The display lights
in the wall switch will come back on and the main burner will stay off for a period of time.
If the set temperature is higher than the room temperature after 4 minutes, the main fl ame
will come on. If the set temperature is lower than the room temperature after 4 minutes,
the main fl ame will stay off until the room temperature drops below the set point.

Wall switch is in THERMOSTAT mode with
the main fl ame OFF and has no battery
backup or has dead batteries.

The fi replace burner is not currently lit and will stay off. The display lights in the wall
switch will be off. When the power is restored to the system, it will return to THERMO-
STAT mode. The display lights in the wall switch will come back on and the main burner
will stay off for a period of time. If the set temperature is higher than the room tem-
perature after 4 minutes, the main fl ame will come on. If the set temperature is lower
than the room temperature after 4 minutes, the main fl ame will stay off until the room
temperature drops below the set point.

Note: If power interruption occurs when the fi replace control was in Thermostat mode and the Timer function was used to shut off
the fi replace, the wall control will revert back to Thermostat mode when the power is restored and turn the unit on and off as room
temperature dictates.

Wall switch is in ON mode with the main
fl ame on and has no battery backup or has
dead batteries.

The fi replace will shut down and the display lights in the wall switch will be off. When
the power is restored to the system it will default to the OFF mode. The display lights in
the wall switch will come back on, the pilot will stay on, and the fi replace will stay off.

The wall switch is in OFF mode with the
main fl ame off and has no battery backup
or has dead batteries.

The fi replace will stay off and the display lights in the wall switch will be off. When the
power is restored to the system, it will stay in the OFF mode. The display lights in the
wall switch will come back on and the fi replace will stay off.

The all switch is in THERMOSTAT mode
with the main fl ame on and it has battery
backup.

The fi replace will stay on and the main burner will turn to HIGH. The FOL*

(Flame on a log) will also have fl ame. The display lights in the wall switch will be off and
the fi replace can be turned on and off by pressing the MODE button.

If the main fl ame is on when the power is restored to the system, it will return to the
THERMOSTAT mode and the display lights in the wall switch will come back on.

If the main fl ame is off when the power is restored to the system, it will go to OFF mode
and the display lights in the wall switch will come back on.

*Not all units using this system have a FOL (Flame on a Log) feature.

The wall switch is in the THERMOSTAT
mode with the main fl ame off and it has
battery backup.

The fi replace main burner will stay off and the display lights in the wall switch will be off.
The fi replace can be turned on and off by pressing the mode button.

If the main fl ame is on when the power is restored to the system, it will return to the ON
mode and the display lights in the wall switch will come back on.

If the main fl ame is off when the power is restored to the system, it will go to OFF mode
and the display lights in the wall switch will come back on.

The wall switch is in ON mode with the
main fl ame on and it has battery backup.

The fi replace will stay on and the main burner will turn to HIGH, the FOL* (Flame on a
Log) will also have fl ame. The display lights in the wall switch will be off and the fi re-
place can be turned on and off by pressing the MODE button.

If the main fl ame is on when the power is restored to the system, it will return to the ON
mode and the display lights in the wall switch will come back on.

If the main fl ame is off when the power is restored to the system, it will go to OFF mode
and the display lights in the wall switch will come back on.