164

Selecting and Using "Other" Features

Running Self Test

N OT E

If any or all of these connections are not made the HP 37718A will FAIL
Self Test.

4

Press

to activate the Self Test. TEST STATUS RUNNING

will be displayed.
The information pertaining to TEST TYPE, TEST NUMBER and
SUBTEST NUMBER will change as the Self Test progresses.
If the HP 37718A is functioning correctly, after a time of at least 1
hour, TEST STATUS PASSED is displayed.
If TEST STATUS [FAIL nnn] is displayed, the HP 37718A should be
returned to a service office for repair.

HOW TO:

Run Confidence TESTS

1

Choose TEST TYPE

on the

display.

2

Insert a formatted disk into the instrument disk drive.

3

Make the loopback connections listed below:
Connect Transmit module 75

OUT to Receive module 75

IN

Connect Transmit module 100/120

OUT to Receive module 100/

120

IN

Connect Transmit module 75

MUX to Receive module 75

DEMUX

Connect Transmit module 100/120

MUX to Receive module 100/

120

DEMUX

Connect Multirate Analyser IN to OUT
Connect Optical OUT to Optical IN via a 15 dB attenuator.

RUN/STOP

CONF. TESTS

OTHER

SELF TEST