Harbor Freight Tools Clear Water Pump 69297 User Manual

Page 5

Advertising
background image

Page 5

For technical questions, please call 1-800-444-3353.

SKU 69297

operation

to pRevent electRic Shock and death:

make sure that the motor cover is properly closed and sealed before priming or operation.

note:

A foot valve on the inlet connection is critical to help prevent the pump from losing prime.

note: Check that the water source and piping are clear of sand, dirt and debris.

1.

pump

bucket

full of

clean

water

priming

hose

outlet pipe

inlet pipe

Foot

valve

Y-fitting

(with one valve

for each outlet)

Connect a bucket full of at least 3 gallons of water

to one side of the Y-fitting using a hose, as shown

above. (If available, a continuous water supply,

such as a spigot, may be used instead.) The bucket

must be positioned higher than the pump’s outlet.

2. Close the valve on the outlet side of the Y-fitting, and

open the valve on the priming side of the Y-fitting.

3. Remove the Priming Plug and wait until water

starts coming out of the Priming Plug. Replace

the Priming Plug and tighten securely.

4. To start the pump:

a. Open the valve on the outlet side of the Y-fitting.
b. Make sure your hands are dry.
c. Plug in the pump.
d. Close the valve on the priming side of the Y-fitting.

caution: do not run the pump dry!

turn off the pump immediatelY if water

stops coming out the outlet.

5. If you operate the Pump and no water comes

out, shut the Pump off IMMEDIATELY. Check the

pipes for air-tightness. Check also that the bottom

of the Inlet pipe is underneath the surface of the

water and a foot valve is properly installed.

6. After the pump is running properly, the priming

hose and bucket can be disconnected.

Storage

1. If you will not be using the Pump for an

extended period of time, drain the Pump

Housing. First disconnect both the suction

and outlet lines, then tip the pump so that all

the water is drained from the pump cavity.

2. If the Pump sits idle for a period of 5 days

or more, it should be unplugged and rotated

with a screwdriver through the middle hole of

the fan cover through several revolutions to

prevent it from taking a permanent set.

3. If you use the Pump only occasionally, when

you are done pumping, replace the Inlet

and Outlet Covers to protect the unit.