Maintenance, Service and repairs, Warning – Hitachi EC 129 User Manual

Page 13: Caution

Advertising
background image

— 13 —

English

(2) If the extension cord does not conform to the

specifications given on page 7 replace with an
extension cord such as that shown on page 7. If
the capacity of the power supply is insufficient,
increase the power supply capacity to remove the
cause of a flow of excessive current (over-current).

(3) Wait approximately 5 minutes, then press the

reset switch of the thermal protector (Fig. 9).

(4) Open the drain cock and confirm that the pressure

gauge (A) indicates 0 PSI (0 bar) (Refer to Fig. 7
and Fig. 8).

(5) Follow steps (2) to (4) in 1. Start up on page 12

and restart. If the motor still stops during
operation, please contact the service center.

Fig. 9

MAINTENANCE

WARNING:

Disconnect the compressor from the
power source and remove the
compressed air from the air tank
before performing the maintenance
operations. Allow the compressor to
cool before performing the
maintenance operations.

1. Cleaning the intake filter

Remove the intake filter (Refer to Fig. 1) every 50
hours or once a week and clean the inside of the
intake filter and the filter element with compressed air
(Fig. 10).

WARNING:

Never clean filter element with a
flammable liquid or solvent.

CAUTION :

Do not operate without the intake

filter.

Fig. 10

Reset switch of thermal protector

NOTE: Replace the filter element when it becomes dirty.

2. Draining tank

Drain tank daily or after 4 hours of use. Open drain
fitting and tilt compressor to empty accumulated
water (Refer to Fig. 8).

3. Oil change-oil topping off

CAUTION:

Overfilling with oil will cause
premature compressor failure. Do not
overfill.

(1) Within the first 50 hours of operation, completely

replace the oil of the pumping element. Unfasten
the oil drain cap on the casing cover, drain all the
oil, and screw the cap back on (Refer to Fig. 1 and
Fig. 11).

Fig. 11

Pour oil into the hole of the dipstick.
To the level indicated on the dipstick (Refer to Fig.
4).
For oil replacement, follow the table below.

OIL TYPE

SAE 5W50 SYNTHETIC OIL

For both summer and winter use

SAE 10W40 MULTI-GRADED OIL

For warm weather use only

(2) Check the oil level of the pumping element every

50 hours or once a week.

(3) Change the oil every 300 working hours or every 6

months.

SERVICE AND REPAIRS

All quality compressors will eventually require servicing
or replacement of parts because of wear from normal use.
To assure that only authorized replacement parts will be
used, all service and repairs must be performed by a
HITACHI AUTHORIZED SERVICE CENTER, ONLY.

NOTE: Specifications are subject to change without any

obligation on the part of the HITACHI.

Drain cap

Intake filter

Filter element

e_ec129_e.p65

4/8/04, 5:38 PM

13