Heat & Glo Fireplace XLR-N-CE User Manual

Page 45

Advertising
background image

45

Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13

WARNING! Risk of Fire! Maintain specified air space

clearances to combustibles. Failure to comply with these

instructions may cause a fire or cause the appliance to

overheat.

= NO SCREWS ALLOWED

= 2,5 cm MAX. SELF-TAPPING SCREWS ALLOWED

= 13 cm – 18 cm SELF-TAPPING SCREWS ALLOWED

FACTORY-INSTALLED

NON-COMBUSTIBLE BOARD

LOWER COVER PANEL

Figure 13.3 Finishing Details

CAUTION! Risk of Glass Damage and Cuts! DO NOT

drill or install any type of screw or fastener into the lower

cover panel. Sharp screw or fastener tips may penetrate

and break the glass or cause cuts.
The XLR-CE must be finished using either the Tonic or

Martini decorative fronts. See Figures 13.11 and 13.12.

The final fireplace installation can be accomplished by ei-

ther the Overlap Fit or Inside Fit method. Reference Sec-

tion 13.C regarding installation details associated with the

Inside Fit and Overlap Fit methods.
It is acceptable to pre-drill holes and use self-tapped

screws in the factory-installed non-combustible board to

attach non-combustible backer board for tile, marble, etc.

Refer to Figure 13.3 for acceptable screw location and

screw length requirements.
Self-tapping screws up to 2,5 cm long can be installed

through the nailing tab and outer 4,5 cm edges of the

factory-installed non-combustible board to secure the

drywall adjacent to the factory-installed non-combustible

board. See Figure 13.3.
Do not drill or install screws which may penetrate the low-

er cover panel as this will restrict required access to the

glass, battery-back-up, and remote receiver. See Figure

13.3.
The appliance is designed to accept 1,3 cm wall sheath-

ing materials such as drywall, plywood, wood composites,

or non-combustible materials. The type of material used

depends whether the installation is an Inside or Overlap

Fit Method. Refer to Section 13.C regarding installation

details associated with the Inside an Overlap Fit meth-

ods.
The factory-supplied non-combustible board must be

used in all installations. It must be directly attached to

structural framing adjacent to the appliance. Screw fas-

teners should be installed in the pilot holes provided in

the outer perimeter of the non-combustible board. See

Figure 13.3.
The factory-supplied board is designed such that its edg-

es will be at the approximate center of the adjacent fram-

ing, assuming it is 1-1/2 in. (3,8 cm) nominal thickness.

This will allow the wallboard joints to occur on the center

of the framing where the panels can be fastened prop-

erly. If the framing thickness is less than 1-1/2 in. (3,8 cm)

nominal, such as with formed steel systems, then it may

be necessary to adjust the adjacent framing dimensions

so that the non-combustible board and wallboard joints

are centered on the framing.

NOTE: It is acceptable to use a high temperature (150 °C

minimum continuous exposure silicone sealant to ad-

here drywall to lower cover panel.

Note: Refer to Section 13.C regarding installation details as-

sociated with the Inside and Overlap Fit methods.

PILOT HOLES (11) TO ATTACH NON-
COMBUSTIBLE BOARD TO FRAMING