Frame Loading Limitations

Leitch 6800/7000 series frames are designed to operate in an ambient
temperature range of 0° to 50°C (32° to 122°F). No special provisions are
necessary other than power loading limitations that should be
considered upon installation.

There are two separate issues to consider with respect to a serial digital
product and its related loading limitations: power supply load
limitations and maximum frame loading limitations.

Power Supply Load Limitations

These are the maximum suggested loading specifications of the power
supply over the operating temperature range 32°F - 122°F
(0.5°C - 50°C). The 6800 series of power supplies come with 120 VAC,
240 VAC, and 48 VDC with inputs -6.5 V and +6.5 V output. Do not
parallel dissimilar supplies.

Module Loading Specifications

See

page 3 for information on power requirements for 6800/7000 series

serial products.

Power Supply Model #

+6.5 Rail Power Limit

-6.5 Rail Power Limit

6801PS

22 W

22 W

6804PS(-1)

78 W

29 W

7000PS

3.75 W

3.75 W

6801PS-48

22 W

22 W

6804PS-1-48

78 W

29 W