Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05

12

Figure 3.

Framing Dimensions for SL D-Series and DVP-Series Pipe

A

B

C

D*

E

*

37”

33”

16 1/4” 36 1/2”

24 3/8

Framing should be constructed of
2 X 4 lumber or heavier. The
framing headers may rest on the
fireplace stand-offs.

WARNING:
To ensure proper clearances
the front framing header must be
installed on its narrow edge and
to the front of the frame.

A

B

C

Step 2. Framing the Fireplace for DVP-Series

and SL D-Series Pipe

Fireplace framing can be built before or after the fireplace is
set in place. Framing should be positioned to accommo-
date wall coverings and fireplace facing material. The dia-
gram below shows framing reference dimensions.

CAUTION: MEASURE FIREPLACE DIMENSIONS AND
VERIFY FRAMING METHODS AND WALL COVERING
DETAILS BEFORE FRAMING.

*The center of the framing hole is one inch (25.4mm)
above the center of the horizontal vent pipe.

VENT

FRAMING

HOLE

E

D